Dxn8d-Q Voltage Indicator Vds for Ring Main Unit Sf6 Rmu Arrester Load Break Switch Breaker Voltage Indicator

Product Details
Task: Live Display
Structure: Combination
Mathematical Model: Non-Linear
Still deciding? Get samples of $ !
Request Sample
Diamond Member Since 2025

Suppliers with verified business licenses

Management System Certification
ISO 9001
  • Dxn8d-Q Voltage Indicator Vds for Ring Main Unit Sf6 Rmu Arrester Load Break Switch Breaker Voltage Indicator
  • Dxn8d-Q Voltage Indicator Vds for Ring Main Unit Sf6 Rmu Arrester Load Break Switch Breaker Voltage Indicator
  • Dxn8d-Q Voltage Indicator Vds for Ring Main Unit Sf6 Rmu Arrester Load Break Switch Breaker Voltage Indicator
  • Dxn8d-Q Voltage Indicator Vds for Ring Main Unit Sf6 Rmu Arrester Load Break Switch Breaker Voltage Indicator
  • Dxn8d-Q Voltage Indicator Vds for Ring Main Unit Sf6 Rmu Arrester Load Break Switch Breaker Voltage Indicator
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
DXN8DQ
Signal
Continuous
Function
Protection, Monitoring
Certification
ISO: 9001, CE
Condition
New
Customized
Non-Customized
Material
Plastic
Rated Voltage
3.6 - 40.5 Kv
Rated Frequency
50 Hz
Ambient Temperature
- 25ºC to + 40ºC
Altitude
Not Higher Than 2,000 Meters
LED Starting Voltage
Bus Voltage × 0.15
Locking Starting Voltage
Bus Voltage × 0.65
Transport Package
Carton
Specification
48× 96× 66mm
Trademark
Comewill
Origin
China

Product Description

Product Description

The DXN8D - Q high - voltage charged display is a charged - state indication and safety - protection device used for indoor high - voltage electrical equipment. It mainly consists of two parts: a sensor and a display. The sensor is usually installed in the cable chamber or bus chamber and is connected to the high - voltage busbar, while the display is mounted on the instrument door of the switch cabinet, used to visually show whether the circuit is charged.

Main Functions

  • Charged Indication: It visually shows whether the high - voltage circuit is charged through the display, reminding operators to pay attention to safety.
  • Forced Locking: It cooperates with the electromagnetic lock to realize the forced locking function of the switch cabinet door, preventing accidental entry into the charged compartment or misoperation.

Features

  • Non - contact Detection: The sensor adopts non - contact technology, which does not need to be in direct contact with the charged body, improving the safety and reliability of detection.
  • Directionality: The sensor has obvious directionality and can accurately detect whether the line is charged.
  • Self - test Function: The device has a self - test function, which can detect whether its working state is normal.
  • Forced Locking Function: Through the locking contact and the electromagnetic lock, it realizes the forced locking of the switch cabinet door to ensure the safety of operators.
  • Low Maintenance Cost: Since the sensor is not in direct contact with the charged body, there is no need to conduct partial discharge tests during installation and maintenance, reducing the maintenance cost.
  • Long Service Life: It adopts advanced technologies and materials to ensure that the device has a long service life.

Technical Parameters

  • Applicable Voltage: It is applicable to indoor high - voltage switchgear such as 6kV, 12kV, 20kV, 27.5kV, and 35kV.
  • Operating Frequency: 50Hz.
  • Ambient Temperature: Usually from - 25°C to + 40°C.
  • Relative Humidity: The daily average is not more than 95%, and the monthly average is not more than 90%.
  • Altitude: Not higher than 2,000 meters.

Application Scenarios

The DXN8D - Q high - voltage charged display is widely used in indoor high - voltage switchgear, distribution rooms, substations, and other places, providing important protection for the safe operation of power systems.

DXN8-Q vs. DXN8D-Q Parameter Comparison Table

Parameter DXN8-Q DXN8D-Q
Product Type Basic HV live-line indicator Smart multi-function HV live-line indicator
Core Functions Live display, optional interlock Live display, forced interlock, voltage test, self-check, phase verification
Rated Voltage 10kV, 12kV, 35kV (up to 40.5kV) 10kV, 12kV, 35kV (up to 40.5kV)
Power Supply AC220V±10%, 50Hz AC220V±10%, 50Hz (customizable)
Power Consumption ≤5W ≤5W
Operating Environment -40ºC~60ºC, ≤95%RH -40ºC~60ºC, ≤95%RH
Withstand Voltage >2000V AC, 1min >2000V AC, 1min
Interlock Output Passive contact (requires external power for solenoid lock) Passive contact (AC250V 5A)
Voltage Test Function No (optional in some models) Yes (with test port, requires voltage detector)
Self-Check Function No Yes (press self-test button to verify status)
Phase Verification No Yes (requires external phase comparator)
Communication Interface No Available in some models (supports remote monitoring)
Dimensions 197×136×62mm (panel-mounted) 48×96×66mm (flush-mounted)
Cutout Size 91×44mm or 102×72mm 45×91mm
Weight 1.1kg 1.1kg
Additional Features Optional heating/dehumidification, fault monitoring Integrated mimic diagram, spring charge status, temperature/humidity control
Dxn8d-Q Voltage Indicator Vds for Ring Main Unit Sf6 Rmu Arrester Load Break Switch Breaker Voltage Indicator
Dxn8d-Q Voltage Indicator Vds for Ring Main Unit Sf6 Rmu Arrester Load Break Switch Breaker Voltage Indicator
Dxn8d-Q Voltage Indicator Vds for Ring Main Unit Sf6 Rmu Arrester Load Break Switch Breaker Voltage Indicator
Dxn8d-Q Voltage Indicator Vds for Ring Main Unit Sf6 Rmu Arrester Load Break Switch Breaker Voltage Indicator
Dxn8d-Q Voltage Indicator Vds for Ring Main Unit Sf6 Rmu Arrester Load Break Switch Breaker Voltage Indicator
Dxn8d-Q Voltage Indicator Vds for Ring Main Unit Sf6 Rmu Arrester Load Break Switch Breaker Voltage Indicator

Dxn8d-Q Voltage Indicator Vds for Ring Main Unit Sf6 Rmu Arrester Load Break Switch Breaker Voltage Indicator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier