Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel

Still deciding? Get samples of $ !
Request Sample
Product Details
Customization: Available
Task: Monitoring
Structure: Combination
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 15 days
Low MOQ
The MOQ for the supplier's products is 1
to see all verified strength labels (18)
Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel pictures & photos
Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel pictures & photos
Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel pictures & photos
Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel pictures & photos
Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel pictures & photos
Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel pictures & photos
  • Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel
  • Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel
  • Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel
  • Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel
  • Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel
  • Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel

Find Similar Products

Overview

Basic Info.

Model NO.
XTKB-100
Mathematical Model
Indicator
Signal
Continuous
Function
Monitoring
Certification
ISO: 9001
Condition
New
Customized
Customized
Material
Plastic
Application
Switchgear/Rmu
Working Voltage
AC/DC 85-265V
Humidity Measurement Accuracy
Less Than Plus or Minus 2%
Frequency
50Hz
Working Temperature
-20~70 Degrees Celsius
Certificate
ISO9001:2008
Operating Environment
-20°c - 70°c,≤95%Rh
Power Consumption
≤10W
Hysteresis
4 - 6°c
Response Speed
Curve - Type Value ≤5s
Transport Package
Carton
Trademark
Comewill
Origin
China

Product Description

1. Analog Indication Instructions

Circuit Breaker Status Indication (Passive Contact Input): When the circuit breaker is closed, the closing contact closes, and the red vertical analog bar lights up; when the circuit breaker is open, the opening contact closes, and the green horizontal analog bar lights up.
Handcart Position Indication (Passive Contact Input): When the working position contact closes, the red vertical analog bar lights up; when the experimental position contact closes, the green horizontal analog bar lights up.
Spring Energy Storage Indication (Passive Contact Input): When the contact closes, the red LED lights up, indicating that energy has been stored; when the contact opens, the green LED lights up, indicating that energy has not been stored.
Grounding Switch Status Indication (Passive Contact Input): When the contact closes, the red vertical analog bar lights up, indicating that the grounding switch is closed; when the contact opens, the green horizontal analog bar lights up, indicating that the grounding switch is open. 
Note: All lighting indications do not light up in the power - off state. The above contact signals are all from the auxiliary contacts of the circuit breaker.

2. High - Voltage Live Indication Part

LED Starting Voltage (KV): Bus voltage × 0.15 - 0.65
Lock - out Starting Voltage (KV): Bus voltage × 0.65
When the three phases are all de - energized, the lock - out is released, and the electromagnetic lock is activated.

3. Temperature and Humidity Control Part

Sensor Channels: XTKB - 100A/XTKB - 100B can be optionally equipped with one - channel condensation and one - channel temperature, or two - channel condensation and two - channel temperature.
Logical Relationship: When the ambient humidity is higher than 85%RH and the conditions for condensation are met, heating is started; when the ambient humidity no longer meets the condensation conditions, the device automatically stops heating. The humidity control accuracy is ±2%RH. When the ambient temperature is lower than 5°C, the system starts heating; when the ambient temperature is higher than 16°C, the system automatically stops heating. The temperature control accuracy is ±2°C.
Forced Heating: When the forced heating switch is in the manual position, the heating output is executed unconditionally. When it is in the automatic position, the device automatically operates according to the above - mentioned control logic.

External Dimensions

Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel

Connection Diagram

Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel

Hot products

Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel
Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel
Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel
Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel
Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel
Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel
Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel
Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel
Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel

Integrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features SteelIntegrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features SteelIntegrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features SteelIntegrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features SteelIntegrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features SteelIntegrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features SteelIntegrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features SteelIntegrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features SteelIntegrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features SteelIntegrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features SteelIntegrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features SteelIntegrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features SteelIntegrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features SteelIntegrated Control Box High-Voltage 240V Switchgear Live Display Phase Detection Voice Prompt 485 Features Steel

Send your message to this supplier

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

People who viewed this also viewed