IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector

Product Details
Certification: CCC
Application: Industrial
Material: EPDM
Still deciding? Get samples of $ !
Request Sample
Diamond Member Since 2025

Suppliers with verified business licenses

Registered Capital
1000000 RMB
Plant Area
>2000 square meters
  • IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
  • IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
  • IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
  • IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
  • IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
  • IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
Find Similar Products
  • Overview
  • After Sales Service
  • Company Profile
Overview

Basic Info.

Model NO.
15kV 200A Elbow Connector
Color
Black
Continuous Operating Voltage
8.7kv/14.4kv
Impulse Withstand Test
95kv
AC Withstand Voltage
42kv/1min
DC Withstand Voltage
53kv/15min
Standard Reference
IEEE592-1990
Maximum Allowable Pd
≤10 PC at 13kv
Transport Package
Carton
Specification
20X30X20cm
Trademark
Comewill
Origin
China

Product Description

General
The 15kV 200A elbow separable connector is a fully - insulated and fully - sealed insert - type terminal that can be touched live. It is widely used for the connection of outdoor distribution transformers, American - style pre - fabricated substations, ring - main units, cable branching boxes, pad - mounted transformers and other electrical equipment. It is installed on the outlet side of T - II type cable heads with a current rating of 200A, 200A busbars, and single - pass (or double - pass) bushing joints and load - break switch joints of American - style pre - fabricated substations, etc. A live indicator can be installed at the test point to check the live status of the equipment, and it can also meet the requirements of line phase - checking.
It uses high - quality EPDM (ethylene - propylene - diene monomer rubber) for insulation. The conductive rod connection head is equipped with arc - extinguishing material, so it can be operated under live conditions, but it cannot interrupt short - circuit current. It can be used as a load switch to interrupt a current of 200A.
It is applicable to cross - linked polyethylene cables with a voltage rating of 15kV and a cable cross - sectional area ranging from 35mm² to 150mm².
Standards
-ANSI IEEE std386 - 2006 600V above the distribution system with the connector system separation insulation;
-ANSI IEEE592 - 1990 high voltage cable joints and can be separated from the exposed semiconductor sheath insulation connector;
-IEC60502 rated voltage of 1 kV (Um = 1.2kV) to 30kV (Um = 36kV) Extrusion insulation power cable and its accessories;
-IEC61442 rated voltage of 6kV (Um = 7.2kV) to 30kV (Um = 36kV) power cable accessories test method;
-GB12706 - 2002 rated voltage of 1kV (Um = 1.2kV) to 35kV (Um = 40.5kV) Extrusion insulation power cable and its accessories;
-GB311.1 - 1997 Insulation coordination for high voltage power transmission and distribution equipment;
-GB/T419 - 1999 high pressure casing technology conditions;
-GB11032 - 2010 AC gasless metal oxide arrester;
-DIN47636 - 7 - 1990 power cable with protruding cone can be divided into the sleeve, Um below 36kV casing and can be divided into the connector device size.
IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
Technical Specifications
(Custom configurations available upon request.)
Item
15kV
25kV
35kV
Rated voltage
8.7kV/14.4kV
15.2kV/26.3kV
26kV/35kV
AC withstand voltage
42kV/1min
55kV/5min
117kV/5min
DC withstand voltage
53kV/15min
78kV/15min
104kV
Impulse withstand voltage
95kV
125kV
215kV
Partial discharge voltage(10pc)
13kV
22kV
45kV
Welcome(Wenzhou)Electric Co.,Ltd
Drawings & Dimensions
15kV/25kV interface&outline dimensions
IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
After Sales Service
Standard Warranty: 12 months or 2,000 operating hours (whichever comes first).
Extended Warranty: Optional coverage up to 36 months.
Global Support: 24/7 technical assistance and spare parts supply.
Training: On-site or remote operation/maintenance training.
Company Profile
IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector
IEEE 15kv 200A Plug - in Cable Connector Deadbreak Loadbreak Switchgear Connector

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier