  • Comewill Switch Cabniet Controller with RS485, Switchgear
  • Comewill Switch Cabniet Controller with RS485, Switchgear
  • Comewill Switch Cabniet Controller with RS485, Switchgear
  • Comewill Switch Cabniet Controller with RS485, Switchgear
  • Comewill Switch Cabniet Controller with RS485, Switchgear
  • Comewill Switch Cabniet Controller with RS485, Switchgear
Find Similar Products
  • Overview
  • External Dimensions
  • Connection Diagram
  • Hot products
Overview

Basic Info.

Model NO.
XTKB-700
Signal
Continuous
Function
Monitoring
Certification
ISO: 9001
Condition
New
Customized
Customized
Material
Plastic
Application
Switchgear/Rmu
Working Voltage
AC/DC 85-265V
Dynamic Flashing Frequency
Twice Per Second
Frequency
50Hz
Power Consumption
≤10W
Hysteresis
4 - 6°c
Response Speed
Curve - Type Value ≤5s
Humidity Control Range
20 - 100%Rh
Temperature Control Range
-20°c - +100°c
Communication Mode
RS485, Modbus Protocol
Anti - Electromagnetic Interference Abil
in Line with The Provisions of IEC255 - 22 Standar
Transport Package
Carton
Trademark
Comewill
Origin
China

Product Description

1. Analog Indication Instructions

  • Circuit Breaker Status Indication (Passive Contact Input): When the circuit breaker is closed, the closing contact closes, and the red vertical analog bar lights up; when the circuit breaker is open, the opening contact closes, and the green horizontal analog bar lights up.
  • Handcart Position Indication (Passive Contact Input): When the working - position contact closes, the red vertical analog bar lights up; when the experimental - position contact closes, the green horizontal analog bar lights up.
  • Spring Energy Storage Indication (Passive Contact Input): When the contact closes, the red LED lights up, indicating that energy has been stored; when the contact opens, the LED does not light up, indicating that energy has not been stored.
  • Grounding Switch Position Indication (Passive Contact Input): When the contact closes, the red vertical analog bar lights up, indicating that the grounding switch is closed; when the contact opens, the green vertical analog bar lights up, indicating that the grounding switch is open.
 
Note: All lighting indications do not light up in the power - off state. The above contact signals are all from the auxiliary contacts of the circuit breaker.

2. High - Voltage Live Indication Part

  • LED Starting Voltage (KV): Bus voltage × 0.15 - 0.65
  • Lock - out Starting Voltage (KV): Bus voltage × 0.65
    When the three phases are all de - energized, the lock - out is released, and the electromagnetic lock is activated.

3. Temperature and Humidity Control Part

  • Sensor Channels: Two channels for condensation and two channels for temperature.
  • Logical Relationship: When the ambient humidity is higher than 85%RH and the conditions for condensation are met, heating is started; when the ambient humidity no longer meets the condensation conditions, the device automatically stops heating. The humidity control accuracy is ±2%RH. When the ambient temperature is lower than 5°C, the system starts heating; when the ambient temperature is higher than 15°C, the system automatically stops heating. The temperature control accuracy is ±2°C.
  • Open - circuit Alarm: When the heater has an open - circuit, the corresponding alarm indicator light lights up, and the alarm output contact closes.
  • Forced Heating: When the forced heating switch is in the manual position, the heating output is executed unconditionally. When it is in the automatic position, the device automatically operates according to the above - mentioned control logic.

4. Voice Error - prevention Function

When the circuit breaker is in the closed state and the handcart is mistakenly pushed from the test position to the working position, a voice prompt "Please open the circuit breaker" will be given.
When the grounding switch is in the closed state and the handcart is mistakenly pushed from the test position to the working position, a voice prompt "Please open the grounding switch" will be given.
When both the circuit breaker and the grounding switch are in the closed state and the handcart is mistakenly pushed from the test position to the working position, voice prompts "Please open the circuit breaker" and "Please open the grounding switch" will be given.

5. Operation Functions

Opening operation, energy - storage operation, remote/local operation, and cabinet interior lighting operation.

6. Optional Function

RS485 communication function.

External Dimensions

Comewill Switch Cabniet Controller with RS485, Switchgear

Connection Diagram


Comewill Switch Cabniet Controller with RS485, Switchgear

Hot products

Comewill Switch Cabniet Controller with RS485, Switchgear
Comewill Switch Cabniet Controller with RS485, Switchgear
Comewill Switch Cabniet Controller with RS485, Switchgear
Comewill Switch Cabniet Controller with RS485, Switchgear
Comewill Switch Cabniet Controller with RS485, Switchgear
Comewill Switch Cabniet Controller with RS485, Switchgear
Comewill Switch Cabniet Controller with RS485, Switchgear
Comewill Switch Cabniet Controller with RS485, Switchgear
Comewill Switch Cabniet Controller with RS485, Switchgear

 

Comewill Switch Cabniet Controller with RS485, Switchgear

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier