High Voltage Indoor Sf6 Gas Isolation Load Break Switch 11-36kv 1250A 630A Gas Air Load Break Switch

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of $ !
Request Sample
Diamond Member Since 2025

Suppliers with verified business licenses

Registered Capital
1000000 RMB
Plant Area
>2000 square meters
  • High Voltage Indoor Sf6 Gas Isolation Load Break Switch 11-36kv 1250A 630A Gas Air Load Break Switch
  • High Voltage Indoor Sf6 Gas Isolation Load Break Switch 11-36kv 1250A 630A Gas Air Load Break Switch
  • High Voltage Indoor Sf6 Gas Isolation Load Break Switch 11-36kv 1250A 630A Gas Air Load Break Switch
  • High Voltage Indoor Sf6 Gas Isolation Load Break Switch 11-36kv 1250A 630A Gas Air Load Break Switch
  • High Voltage Indoor Sf6 Gas Isolation Load Break Switch 11-36kv 1250A 630A Gas Air Load Break Switch
  • High Voltage Indoor Sf6 Gas Isolation Load Break Switch 11-36kv 1250A 630A Gas Air Load Break Switch
Find Similar Products
  • Overview
  • Specification
  • Hot-Selling Products
  • Packing & Delivery
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
FLN36-12/24/36KV
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
SF6
Installation
Fixed
Structure
Cabinet
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB, Circuit-Breaker
Certification
VDE, CCC
Place of Origin
Zhejiang, China
Rated Frequency
50Hz
Rated Voltage
24kv / 36kv or Others
Color
Red
Mechanism
Motor or Manual
Current
AC
Transport Package
Carton
Specification
45*45*50cm
Trademark
Comewill
Origin
China
HS Code
8538900000
Production Capacity
50000PC/Month

Product Description

Specification
12KV SF6 load break switch 
The load breaker switch is a kind of door type medium voltage switchgear with multiple functions. It has three working states: closed, open and grounded. Fully sealed, reinforced epoxy shell structure, filled with SF6 gas, 0.05Mpa. SF6 gas is used as the arc extinguishing insulation medium, and epoxy resin is poured into the main circuit through the upper and lower shell, so that the conductive function is not affected. The minimum parts are used to achieve the above three functions, ensuring product quality, improving reliability, maintenance free, convenient and safe operation.
High Voltage Indoor Sf6 Gas Isolation Load Break Switch 11-36kv 1250A 630A Gas Air Load Break Switch
The technical parameters of the form are for reference only.
Customized products can consult online customer service!
Item NO.
Name
Unit
Technical parameters
Load break switch panel
1
Rated Voltage Un
kV
12
24
36
2
Rated Frequency
Hz
50
50
50
3
Rated current
A
630
630
630
4
Rated Short Time Withstand Current(rms)
A
630
630
630
5
Rated Short Time Duration
kA
20
20
20
6
Rated Short Time Duration
s
3
3
3
7
Rated Peak Withstand Current
kA
50
50
50
8
Rated Closed Switch - Off Current
A
630
630
630
9
Rated Cable Charging Breaking Current
A
10
10
10
10
Rated Active Load Breaking Current
A
630
630
630
11
Earthing Switch 2s Short Time Withstand Current
kA
20
20
20
12
Rated Short-Circuit Current Making Times
times
2
2
2
13
Rated Current Breaking Times
times
10
10
10
14
Mechanical Endurance
Load Break Switch
times
3000
3000
3000
Earthing Switch
times
2000
2000
2000
15
SF6 gas anual leakage rate≤
/year
0.10%
0.10%
0.10%
16
Rated Insulation Level
Unit
Technical parameters
1min Power Frequency withstand voltage(rms)
On isolating distance
kV
48
60
110
Phase to Phase
kV
42
50
85
Phase to Earth
kV
42
50
85
Lightning impulse withstand voltage(peak)
On isolating distance
kV
85
145
215
Phase to Phase
kV
75
125
185
Phase to Earth
kV
75
125
185
High Voltage Indoor Sf6 Gas Isolation Load Break Switch 11-36kv 1250A 630A Gas Air Load Break Switch
Ambient condition
1. Altitude: ≤1000m;
2. Ambient temperature: -25ºC ~+40ºC ;
3. Relative humidity: daily average≤95% , monthly average≤90% ;
4. Earthquake intensity: ≤8 degree;
5. Occasions without flammable and explosive matter, without corrosive chemical and frequent severe vibration
Hot-Selling Products
High Voltage Indoor Sf6 Gas Isolation Load Break Switch 11-36kv 1250A 630A Gas Air Load Break Switch
High Voltage Indoor Sf6 Gas Isolation Load Break Switch 11-36kv 1250A 630A Gas Air Load Break Switch
High Voltage Indoor Sf6 Gas Isolation Load Break Switch 11-36kv 1250A 630A Gas Air Load Break Switch
Vacuum Circuit Breaker
Separable Connector
Heater



High Voltage Indoor Sf6 Gas Isolation Load Break Switch 11-36kv 1250A 630A Gas Air Load Break Switch
High Voltage Indoor Sf6 Gas Isolation Load Break Switch 11-36kv 1250A 630A Gas Air Load Break Switch
High Voltage Indoor Sf6 Gas Isolation Load Break Switch 11-36kv 1250A 630A Gas Air Load Break Switch
Intelligent Control Device
Current Transformer
Voltage Transformer

Packing & Delivery
High Voltage Indoor Sf6 Gas Isolation Load Break Switch 11-36kv 1250A 630A Gas Air Load Break Switch
Packing SpecificationsInner Packaging
Fuses are individually wrapped in anti-static foam or plastic sleeves to prevent abrasion.
Moisture-proof desiccant packets are inserted for sea transport.
Outer Packaging
Cartons: Made of 5-ply corrugated cardboard with load-bearing capacity ≥50kg.
Wooden cases (optional): For bulk orders, reinforced with steel straps and shockproof padding.
Delivery Terms
Lead Time
Standard orders (≤100 units): 7-10 working days after payment confirmation.
Bulk orders: 15-25 working days (subject to production schedule).
Company Profile
Welcome (Wenzhou) Electric Co., Ltd.: Innovation Leader in Smart Power Sector
Enterprise Positioning and Core Competitiveness
As a national high-tech enterprise, Welcome (Wenzhou) Electric Co., Ltd. positions itself as a "Smart Guardian of Power Systems," focusing on creating full-lifecycle value for high and low voltage power equipment. The company has established an integrated industrial chain covering cutting-edge technology R&D, precision intelligent manufacturing, and global services. With international certifications such as ISO 9001 and IEC standards, it provides safe and reliable power solutions for power grids, new energy, and industrial automation sectors in over 50 countries worldwide.
 
Three Core Product Lines: Technological Breakthroughs Enabling Scenario-Based Applications
1. Cable Accessories: Redefining Power Connection Standards
Specializing in 15-35kV cold-shrink power cable accessories, these products feature high insulation performance, corrosion resistance, and rapid installation capabilities.
2. Switchgear Auxiliary Equipment: Revolutionizing Smart Moisture-Proof Technology
The intelligent dehumidification device adopts a modular design for precise humidity control and low-power operation, ensuring stable equipment performance.
3. Measurement and Control Systems: Building a Digital Neural Network for Power Systems
High-precision current/voltage transformers and intelligent monitoring devices comply with IEC standards, widely applied in power grids, new energy, and industrial fields.
 
Vision and Mission
As a global leader in smart power equipment, Welcome Electric is committed to driving energy industry transformation through technological innovation and building a "safer, more efficient, and greener" power future. The company will continue to center on customer needs, leverage technological innovation as a driving force, and contribute Chinese wisdom and solutions to global energy transition.
High Voltage Indoor Sf6 Gas Isolation Load Break Switch 11-36kv 1250A 630A Gas Air Load Break Switch
High Voltage Indoor Sf6 Gas Isolation Load Break Switch 11-36kv 1250A 630A Gas Air Load Break Switch
High Voltage Indoor Sf6 Gas Isolation Load Break Switch 11-36kv 1250A 630A Gas Air Load Break Switch
FAQ
1. About the Product
Q: What is the rated voltage range of high-voltage high-breaking-capacity fuses?
A: Conventional models cover 7.2kV to 40.5kV, and some imported products reach 72.5kV. Please select the type according to the system voltage.
Q: How to distinguish the breaking capacity of fuses?
A: Check the nameplate parameters. The breaking capacity of domestic models is usually 50kA, and high-end imported products can reach 63kA (both refer to the effective value of rated short-circuit breaking current).
2. Selection and Application
Q: How to select the fuse specification for transformer protection?
A: The rated current of the fuse element is recommended to be 1.5-2 times the rated current of the transformer (e.g., select a 100-125A fuse for a 1000kVA/10kV transformer).
Q: Can it be used in DC systems?
A: Conventional products are suitable for AC systems. DC fuses with special arc-extinguishing structures should be selected for DC scenarios.
3. Installation and Maintenance
Q: What inspections are required before installation?
A: Confirm voltage class matching and no damage to the fuse element, and measure the insulation resistance of the base with an insulation tester (≥1000MΩ).
Q: Can the fuse be directly replaced after it blows?
A: First troubleshoot the cause (e.g., line short circuit), replace the fuse element with the same model, and check the contact resistance (≤50μΩ).
4. Certifications and Standards
Q: Which international standards do the products comply with?
A: Comply with IEC 60282-1 and IEEE C37.40. Some models are certified by KEMA/UL (certificate copies can be provided).
Q: What is the warranty period?
A: The warranty period is 18 months under normal use, and free replacement is provided for failures caused by manufacturing defects.
Note: Specific model parameters may be adjusted due to technical upgrades. Please confirm the latest specification before placing an order.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier